Calsys 30 110 Dry block

Autocal -30/110 SP

Part Code: Autocal-30/110 SP

  • Temperature Range: -25°C to 150°C
  • Stability: ±0.01°C or Better
  • Resolution: 0.01°C or better
Request a Quote

Autocal -30/110 SP easy to use portable low-temperature calibrator with a temperature range from -25 to 150°C. It is a highly stable standard furnace for calibration and also nd application in aerospace, oil gas petrochemical, pharmaceutical industry, electric power, automotive and material process industry.

SPECIFICATIONS

ITEM DESCRIPTIONSPECIFICATION
FunctionMetrological purpose (for calibration of Pt 100 and temperature gauges)
Temperature Range-25°C to 150°C
Operating temperature23°C
Accuracy (when internal
reference sensor)
±0.25°C or better
Stability±0.01°C or Better
Stability (with External
Reference Sensor)
±0.01°C or Better
Resolution0.01°C or better
Heating TimeMaximum 50 minutes from ambient to 150°C
Cooling TimeMaximum 30 minutes from ambient to -25°C
Readout for Master/external
reference sensor
It has an inbuilt readout for an externally connected Master/reference RTD sensor (PT100)
Readout for Instrument under test (IUT)It Has an inbuilt readout for instruments under test.
Resistance (RTD)0-300 ohms (with accuracy 0.009 ohm or better)
Inserts SpecificationProvision of 4 insert combination of 25mm dia for external reference RTD and DUT (RTD) with options to insert 1(12mm, 3mm, 4mm, 5mm) Insert 2(10mm, 4mm, 8mm, 6mm), Insert 3 (3mm, 4mm, 5mm, 6mm) Insert 4 (16mm, 3mm)
Depth (Has sufficient depth to control stem conduction)Minimum 140 mm
Weight12 kg
Size380(H) x 170(W) x 188(D) mm
Computer InterfaceEthernet
DisplayLCD, Unit: °C
Inputs on InstrumentInstrument to have connections for RTD (reference probe) 4 wire RTD (IUT) and Thermocouple (K type – IUT).
Input Measurement Channels and quantity

(i) RTD (PT100) reference sensor – 1 No. min.

(ii) 4 wire RTD – 1 No. min.

(iii) K type Thermocouple – 1 No. min.

If the input at sl. (ii) and (iii) use a connector plug then 5 nos. of extra connecters for each input to be provided.

  • Wide Temperature Range
  • Lightweight, portable
  • Accuracy and performance
  • Accredited calibration
  • Highly accurate & Automatic Dry Block Calibrator for Industrial/Laboratory field use