Tempsens offers wide range of Thermocouple, Extension & Compensating Cables suitable for various applications with maximum temperature range up to maximum 1200 Deg C.
Thermocouple Cables have Original thermocouple Grade conductor material having Class 1 accuracy whereas Extension & compensating cables have class 2 accuracy conductor material complying to IEC 584.3 & ANSI MC 96.1 standards. Extension & Compensating wires are used to extend a thermocouple signal form sensor to the instrument for reading
Specifications
Conductor Material
Chromel (+) & Alumel (-)
Conductor
Thermocouple Grade Class 1
Conductor Size
32 AWG Solid
No. of pairs
01
Design
Fiber Glass - Fiber Glass
Cable formation
Flat Style
Temperature Range
Up to 450 °C
Colour Code
Green Thread (+) & White (-) / Green Thread
Colour Code Standard
IEC 60584.3
Thermal EMF Error (Accuracy)
+/- 1.5 Deg C or 0.4 % whichever is higher as per IEC 584.3