When industrial processes are challenged by temperature fluctuations, maintaining a proper thermal condition is crucial for preserving process integrity and protecting equipment. At Tempsens, we design and engineer heat tracing systems that enable consistent temperature maintenance across most industrial process applications, allowing operations to continue despite the extreme environments they face.
Industrial heat tracing is fundamental to temperature management in modern facilities; addressing the growing number of applications such as avoiding freeze damage in chemical processing lines, ensuring the correct viscosity of petroleum as it moves to distribution points, and maintaining proper temperature during pharmaceutical manufacturing. Tempsens heat trace systems provide the thermal reliability that industrial operations rely upon.
Every facility manager is painfully aware of the costs associated with temperature failures; whether it is burst pipes, crystallized product, poor process quality or unplanned downtime. Engineered heat tracing products provide facility managers with the smart, or engineered response with a robust built to last approach, while delivering immediate protection and value over time.


MI High Temperature Heating Cable
Cable calefactor de alta temperatura con aislamiento mineral

Mineral Insulated Heat Trace Cable (MIHT)
Cable de trazado de calor con aislamiento mineral (MIHT)

Self Regulating Heating Cable (HTSRH)
Cable de trazado térmico autorregulable de alta temperatura (HTSRH)

Constant Wattage Series Heat Trace Cable (CWSHT)
Constant Wattage Series Heat Trace Cable (CWSHT)

Constant Wattage Parallel Heat Trace Cable (CWPHT)
Constant Wattage Parallel Heat Trace Cable (CWPHT)

Self Regulating Heating Cable (MTSRH)
Cable de trazado calefactor autorregulable de temperatura media (MTSRH)

Self Regulating Heating Cable (LTSRH)
Low Temperature Self Regulating Heat Tracing Cable (LTSRH)
About Heat Tracing Solutions
Heat Tracing Solutions Key Features
Self-Regulating Heating Cables
Utilizing smart polymer technology, self-regulating heating cables automatically adjust heat output based on ambient conditions – increasing heat output when cold and decreasing consumption when warm – energy efficient operation without external controls.
Constant Wattage Parallel Systems
Consistent power output per meter is usable with constant wattage parallel systems, where it would be in common construction that keeps power delivered without variation to the cable if a section of the circuit fails, ensuring the same heat output through any length of connection in the circuit.
Cables con aislamiento mineral
Designed with durable metal sheathing with magnesium oxide insulation, these cables can withstand temperatures as high as 955°C while still providing consistent heating with the benefit of the best corrosion resistance and the ability to tolerate extreme and harsh industrial application conditions.
Operating Temperature Performance Range
Operates from -40°C install conditions to the maximum operating temperature of 800°C with flexible construction to accommodate some of the most complicated piping configurations, and custom lengths available to meet exact installing pipe lengths.
Electrical Protection Systems
Compatible with voltages ranging from 110V to 277V with advanced braided shielding with 85%+ coverage, electrical protection systems will integrate with existing infrastructure while providing electromagnetic and mechanical protection.
Applications of Heat Trace Systems
- Chemical processing facilities utilise heat tracing applications to prevent crystallisation in transfer lines, maintain reaction temperatures in process vessels, and ensure consistent product flow through complex piping networks. Tempsens Self-regulating cables provide energy-efficient temperature maintenance while preventing thermal damage to sensitive compounds.
- Oil and gas operations depend on commercial heat trace solutions for freeze protection in wellhead equipment, wax prevention in crude oil pipelines, and flow assurance in natural gas distribution systems. Tempsens Constant wattage systems deliver reliable performance across extended pipeline distances where uniform heat distribution is critical.
- Farmacéutica manufacturing requires precise temperature control throughout sterile processing environments. Heat tracing systems maintain validated temperature ranges in transfer lines, prevent condensation in clean rooms, and ensure product integrity during temperature-sensitive manufacturing processes.
- Potencia generation facilities protect critical instrumentation and process lines from freeze damage while maintaining optimal operating temperatures for boiler systems, cooling circuits, and chemical feed lines. Mineral-insulated cables provide reliable service in high-temperature turbine and heat exchanger applications.
- Food processing operations utilise industrial heat tracing solution technology to maintain food safety temperatures during transport, prevent thermal shock in processing equipment, and ensure consistent product texture in temperature-controlled manufacturing environments.
Heat Trace Solutions from Tempsens
LTSRH Series
Low-temperature self-regulating cables (10-35 W/m at 10°C) with maximum maintenance temperatures of 65°C and exposure ratings to 105°C, ideal for freeze protection applications.
MTSRH Series
Medium-temperature self-regulating systems (40-60 W/m at 10°C) featuring polyolefin or fluoropolymer insulation will maintain temperatures to 105°C and maximum exposure of 135°C.
HTSRH Series
High-temperature self-regulating cables (40-65 W/m at 10°C) with fluoropolymer construction, maintaining temperatures to 135°C with exposure ratings of 205°C for demanding process applications.
CWPHT Series
Constant wattage parallel heat trace systems (10-65 W/m) with PTFE insulation, delivering consistent output at surface temperatures up to 200°C for precision temperature control.
CWSHT Series
Constant wattage series resistance cables supporting circuit lengths up to 1.5 kilometers with customizable wattage ratings for extended pipeline applications.
MIHT Series
Mineral insulated heat trace cables with Incoloy 825 or stainless steel sheathing, operating at surface temperatures to 800°C with maximum exposure ratings of 955°C for extreme environments.
PREGUNTAS FRECUENTES
Preguntas frecuentes
Find answers to frequently asked questions related to Heat Tracing Solutions.
Heat tracing systems generate controlled heat through electrical resistance in heating elements distributed along pipes and equipment surfaces. Self-regulating cables automatically adjust output based on temperature conditions, while constant wattage systems provide consistent heat regardless of ambient temperature.
Chemical processing, oil and gas, pharmaceuticals, food processing, power generation, and manufacturing industries rely on heat tracing products for freeze protection and process temperature control. Any facility requiring precise temperature maintenance or protection from thermal extremes benefits from properly engineered heat trace systems.
Modern heat trace systems require minimal maintenance with periodic visual inspections and annual electrical testing of insulation resistance and continuity. Tempsens systems include comprehensive accessories like termination kits, junction boxes, and control panels to ensure reliable long-term operation with minimal service requirements.