PRODUCTOS
ACERCA DE
Cables de termopar
Thermocouple cables are specialized electrical conductors that transmit signals generated by thermocouple sensors to measurement instruments without degradation of the signals.These cables ensure the thermoelectric characteristics of the thermocouple circuit are preserved, allowing accurate temperature readings to be transmitted throughout industrial and commercial settings.
Tempsens offers thermocouple extension and compensation cables manufactured to the Seebeck coefficient of the associate thermocouple types—including Type K (Chromel-Alumel), Type J (Iron-Constantan), Type T (Copper-Constantan), Type E (Chromel-Constantan), and noble metal types R and S (Platinum-Rhodium alloys). The cables are constructed from conductors from 20 AWG to 24 AWG and with insulation materials including PVC, fiberglass, silicone rubber and PTFE to suit different temperature ranges and environmental conditions. Simplex, duplex and multipair types of cables are available from distances of installations to the remote sensors while maintaining an accuracy level to have a reading within ±0.5°C to ±2.2°C according to IEC 60584.


FP-101
Cable de termopar FP-101
FEP - AISLADO CON FEP - 200°C

FP-601
Cable de termopar FP-601
Apantallamiento de poliimida de cobre y FEP - FEP - 200 °C

FP-501
Cable de termopar FP-501
Aislamiento de silicio FEP - 200°C

FP-401
Cable de termopar FP-401
Apantallamiento de FEP-Poliimida-Cobre-Trenzado de FEP-SS - 200°C

FP-301
Cable de termopar FP-301
FEP-Almyler-FEP-200°C

FP-201
Cable de termopar FP-201
Trenzado FEP-FEP-SS aislado - 200°C

T-601
Cable de termopar (T-601)
PTFE - AISLADO CON SILICIO - 200°C

T-451
Cable de termopar (T-451)
Trenzado de poliimida-PTFE-poliimida-PTFE-MICA-FG-SS aislado - 450°C

T-351
Cable de termopar (T-351)
PTFE-PTFE-MICA-Fibra de vidrio aislada - 350°C

T-251
Cable de termopar (T-251)
Malla de PTFE-Poliimida-Cobre-Trenzado de PTFE-Amianto - 300°C

T-151
Cable de termopar (T-151)
Apantallamiento de PTFE-Poliimida-Cobre-Aislamiento de Silicio - 200°C

T-801
Cable de termopar (T-801)
Trenzado de PTFE-PTFE-amianto aislado 300 °C

T-701
Cable de termopar (T-701)
PTFE-Fibra de vidrio-Fibra de vidrio-400°C

T-501
Cable de termopar (T-501)
PTFE - Poliimida - Blindaje de cobre - Aislamiento de PTFE - 260 °C

T-401
Cable de termopar (T-401)
PTFE - PTFE - Trenzado de acero aislado - 260°C

T-301
Cable de termopar (T-301)
Pantalla de PTFE Almyler aislada con PTFE a 260 °C

T-201
Cable de termopar (T-201)
PTFE-PTFE aislado 260 °C

T-101
Cable de termopar (T-101)
Par trenzado de PTFE - 260 °C

S-401
Cable de termopar (S-401)
Cinta de poliéster-silicio-trenzado de cobre-aislamiento de silicio - 200°C

S-301
Cable de termopar (S-301)
Trenzado de silicio-fibra de vidrio-acero inoxidable - 200°C

S-201
Cable de termopar (S-201)
Pantalla de silicio-Almyler-silicio - 200°C

S-101
Cable de termopar (S-101)
Aislamiento de silicio-silicio - 200°C

P-501
Cable de termopar (P-501)
Trenzado PVC-PVC-SS aislado - 90°C

P-401
Cable de termopar (P-401)
Blindaje PVC-Almyler-PVC-GI-aislado con PVC - 90°C

P-301
Cable de termopar (P-301)
Apantallamiento PVC-Almyler-PVC - 90°C

P-201
Cable de termopar (P-201)
Aislamiento PVC-PVC - 90°C

P-101
Cable de termopar (P-101)
Cinta de PVC-Poliéster-Trenzado de Cobre-PVC - 90°C
About Thermocouple Cables
Key Features of Thermocouple Cables
- Temperature Range of the Insulation: PVC insulation from -20°C to +105°C. Fiberglass braids rated for 400°C continuous use. Silicone rubber rated for -60°C to +180°C. Flat PTFE rated for extending service up to 260°C in extreme environments.
- Multi-Conductor Configurations: Available with 2-wire (simplex), 4-wire (duplex), or multipair (up to 24 measurement points) configurations for unique cable runs.
- Shielding Choices: Tinned copper braid or aluminum-polyester foil, or a combination shielding approach with a shielding effectiveness ranging from 85-95% for EM noise in an electrically noisy environment.
- Conductor Construction: stranded conductor designs from 7×0.2mm up to 19×0.18mm to provide good flexibility routing through duct-work ac while remaining mechanical robust.
- Jacket Options: Outer jackets constructed of PVC, silicone, or fiberglass rated to resist oils, acids, alkalis, and abrasion in rugged industrial environments.
- Accuracy Specifications: Extension grade cable certified to ±2.2°C or ±0.75% accuracy or compensation cables certified for either Type R or Type S noble metal thermocouples, to the limit of temperature limits.
Specifications of Thermocouple Cables
| Construcción | Núcleo único/múltiple |
| Grado de voltaje | Hasta 1,1 kV |
| Conductor | TC, EX, C |
| Tipo de Conductor | K, T, J, E, N, R, S, B, D, C |
| Tamaño del conductor | AWG 12 a AWG 32 |
| Trenzado de conductores | Sólido o multihilo |
| Aislamiento del núcleo | PVC, XLPE, LSZH, PE, PTFE, FEP, PFA, PEEK, silicio, ETFE, poliimida, fibra de vidrio, fibra de cerámica, fibra de alúmina |
| Cribado | Tipo de papel de aluminio/Tipo de malla trenzada |
| Vaina interior/exterior | PVC, LSZH, PTFE, FEP, PFA, ETFE, silicio, poliimida, fibra de vidrio, fibra cerámica |
| Blindaje | Blindaje GI/trenzado SS (para aislamientos de alta temperatura) |
| Código de color | Según la tabla de códigos de colores |
| Normas | ANSI MC 96.1, IEC 584.3, IS 8784 |
Código de colores y precisión de cables de termopar, extensión y compensación

Applications of Thermocouple Cables
- Electric Generation: Circuits that monitor temperature within boiler, turbine, and exhaust gas application test circuits, with cable runs greater than 50 to 100 meters from sensing to control point.
- Metal Processing: Measurement of furnace temp in steel mills, foundries, and heat treatment applications where the cables are rated for 200°C ambient.
- Petrochemical Refineries: Hazardous area installations using armored or explosion-proof cable constructions rated inexpensive with IECEx or ATEX.
- Laboratory Instrumentation: Measurement applications requiring shielded low-noise cables when on research furnaces, environmental chambers and calibration instruments.
Why Choose Tempsens?
- Custom Engineering: Engineering cable designs for specific applications using armored, jacket materials, and hybrid constructions of power and signal conductors.
- Global Standards: Products to meet international thermocouple standards; ANSI standard color codes in North America; IEC standards in Europe.
- Quality Testing: 100% continuity testing, insulation resistance testing at 500V DC and thermoelectric homogeneity testing to ensure zero defects prior to shipment.
- Technical Support: Offering application expertise of cable selection based on temperature range, ambient conditions, distance from installation, and EMI environment.
PREGUNTAS FRECUENTES
Preguntas frecuentes
Find answers to frequently asked questions related to Thermocouple Cables.
Standard thermocouples have a 2-wire or (Positive and Negative Leg) configuration; the 3-wire adds the ground wire providing shielding and safety in electrically-noisy environments, but again, Thermocouples operate 2-wire inherently unlike the RTD style of temperature sensing.
Thermocouple cables can reach lengths of 300-500 meters depending on the gauge of wire and the electromagnetic interference (EMI) in the environment; anything beyond that, it is recommended to utilize signal amplifiers or signal transmitters to prevent noise related errors and to maintain an accurate measurement.
The temperature rating of the thermocouple cable varies based on insulation type. PVC insulation can be rated in the range of -20°C to +105°C, while fiberglass braided cable can be continuous up to 400°C. Silicone rubber feeling can maintain -60 Celsius to +180 °C, while Teflon insulation can operate applications down to -200 Celsius to up to 260 Celsius.







