Dry Block Calibrators (Calsys -100/40 Autocal)

Temperature Range*: -100°C to 40°C

Stability (30 Min): ±0.04 °C or Better

Cooling Time: 70 Min ( Ambient 25°C to -100°C)

Method of Control: Self tunned PID controller

Calibration: Accredited calibration certificate provided

In stock
SKU
Calsys -100/40 Autocal

Part Code: Calsys -100/40 Autocal

₹0.00

Details

Calsys -100/40 Autocal offers easy to use portable low-temperature calibrator with a temperature range from -100 to 40°C. It is a highly stable standard furnace for calibrating RTD. This calibrator can be used on-site for high-temperature calibration and also find application in aerospace, oil gas petrochemical, pharmaceutical industry, electric power, automotive and material process industry.

Specifications

SPECIFICATIONS

Temperature Range* -100°C to 40°C
Stability (30 Min) ±0.04 °C or Better
Radial Uniformity ±0.05°C or better
Immersion Depth** 150 mm
Method of Control Self tunned PID controller
Cooling Time 70 Min ( Ambient 25°C to -100°C)
Stabilization Time 15-20 Min
Resolution 0.1 °C (0.01 Optional)
Display LCD, °C, or °F user-selectable
Size (H x W x D) 545(H) x 245(W) x 350(D) mm
Weight 16Kg
Power Requirements 230 VAC or 110 VAC 50/60 Hz 350W
Computer Interface USB/ LAN
Calibration Accredited calibration certificate provided (Optional)
Environmental Operating Conditions 12 °C to 35 °C, 0 % to 90 % RH (non-condensing)
Specifications valid in environmental
conditions
15°C … 30°C
Input (Autocal -100/40) Four channels (one master and three test sensors).high quality universal LEMO connector suitable both for T/C (J,
K, N,T,R,S, B type) and Rtd
Software (Autocal -100/40) The calibrator will be provided with software for data recording (Manual Mode ) and Excel generation in Auto Mode.

At 25°C  Ambient Temperature

**120mm Deep Plus 30 mm top insulation

Note : Customized options available for resolution and insert construction

Key Features

  • Wide Operating Range (-100°C to 40°C)
  • Lightweight, portable
  • Speed
  • Accuracy and performance
  • Cooling Technology
  • Accredited calibration
  • Computer Interface

Accessories

  • NABL accredited calibration certificate - 3 point(Optional)
  • Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging.
  • Operational Manual
  • Tempsens makes customized carry case is a rugged, safe perfectly designed to carry our new Calsys -100/40 & Calsys -100/40 Autocal
    calibrator and different accessories.

Reviews

Write Your Own Review
You're reviewing:Dry Block Calibrators (Calsys -100/40 Autocal)