PRODUCTS
ABOUT
Introduction
The Tempsens cable floor heating systems give off radiant heat at low temperatures, creating a comfortable and energy efficient alternative for residential and commercial installations. All electric floor heating cables have a rated output between 6 and 17 watts/meter, work from a standard 230V AC circuit, and include a 30 year warranty. Each electric floor heating cable has 100% aluminum shielding, insulation from aluminum foil, cross-linked polyethylene, ethylene tetrafluoroethylene, polyvinylidene fluoride, and heat-resistant PVC jackets for ultimate durability and trouble-free operation underneath any floor coverings.


FHC-DE-240V-03
Floor Heating Cable (FHC-DE-240V-03)
0.125mm2 /0.54mm2 CuNi/Cu/SS/kanthal- Two Core Solid, ETFE Insulation, TPC 1.0mm² (Multi-strand) Earth Wire, Power Output 03 Watt / Foot

FHC-DE-120V-03
Floor Heating Cable (FHC-DE-120V-03)
0.07mm2 /0.35mm2 CuNi - Two Core, ETFE Insulation, TPC 1.00mm² (Multi-strand) Earth Wire, Power Output 03 Watt / Foot

FHC-SX-17
Floor Heating Cable (FHC-SX-17)
0.11mm2 /0.34mm2 CuNi/SS- Single Core, XLPE Insulation, TPC 0.75mm² (Solid) Earth Wire, Power Output 17 Watt / Meter

FHC-DF-15.7
Floor Heating Cable (FHC-DF-15.7)
0.050mm2 /0.13mm2 CuNi- Two Core, FEP Insulation, TPC 0.50mm² (Multi-strand) Earth Wire, Power Output 15.7 Watt / Meter

FHC-SP-15.7
Floor Heating Cable (FHC-SP-15.7)
0.013mm2 /0.36mm2 CuNi/SS/Kanthal/Cu- Single Core, PTFE Insulation, TPC 1.0mm- 1.25mm (Multi-strand) Earth Wire, Power Output 15.7 Watt / Meter

FHC-SP-12.5
Floor Heating Cable (FHC-SP-12.5)
0.013mm2 /0.36mm2 CuNi/SS/Kanthal/Cu- Single Core, PTFE Insulation, TPC 1.0mm - 1.20mm (Solid) Earth Wire, Power Output 12.5 Watt / Meter

FHC-SX-10
Floor Heating Cable (FHC-SX-10)
0.028mm2 /0.40mm2 CuNi/SS- Single Core, XLPE insulation, TPC 1.0mm (Solid) Earth Wire, Power output 06 Watt / Meter

FHC-SX-06
Floor Heating Cable (FHC-SX-06)
0.076mm2 /0.30mm2 CuNi/SS-Single Core,XLPE insulation, Multi-strand Earth Wire, Power output 06 Watt / Meter
About Floor Heating Cables
Construction of Floor Heating Cables
- Resistance conductors made using CuNi/SS/Kantahl/Cu (single or dual core)
- XLPE, PTFE, FEP, or ETFE insulation around heating element
- 100% coverage of aluminium foil shielding to provide electromagnetic shielding
- Grounding using solid or stranded TPC grounding wire
- HR-FR PVC outer jacket (heat and flame resistant)
- 3.5 metre long terminated cold lead wire supplied free from factory.
Key Features of Floor Heating Cables
| Feature | Specification |
|---|---|
| Power Output Range | 6 W/m to 17 W/m (230 V AC); 3 W/ft (120 V and 240 V AC) |
| Shielding Coverage | 100% Aluminium Foil |
| Bending Radius | Minimum 5 times cable thickness |
| Jacketing | Heat resistant and flame retardant PVC (HR-FR) |
| Core Insulation | 3.5 m standard; customisable on request |
| Heat Load Range | 100 W to 3300 W (standard models) |
| Insulation Types | XLPE, PTFE, FEP, ETFE |
| Standard Voltage | 230 V AC; also available in 120 V and 240 V AC |
| Warranty | 30 years against manufacturer’s faults |
| Custom-Built Option | Length, heat load, and voltage customisable |
Applications of Floor Heating Cables
- Residential rooms, like living rooms or bedrooms
- Bathrooms or wet areas that need to use a moisture-resistant underfloor heating cable
- Commercial buildings requiring zoned electric underfloor heating cables
- Kitchens or utility areas that will be covered with tile or stone flooring
- Low energy homes utilizing primary radiant heat below plywood
- Tape down installations using pre-assembled fiberglass heating mats
Benefits of Using Floor Heating Cables
- Reduce energy consumption by 20-40% compared to traditional heating systems.
- Heat the person or object directly, before they heat the air.
- Quiet operation with no moving parts and no routine maintenance required.
- Thin cable enables low height of cable after installation.
- Digital thermostat allows for individual room thermoregulation.
- 100% earthing and shielding for electrical safety for the entire service life.
Why Tempsens Is the Leading Manufacturer of Floor Heating Cables
- NABL accredited lab for product quality verification and assurance
- Manufacturing facilities in India, Germany and Indonesia
- Exported to 75+ countries around the globe
- Custom electric floor heating cables can be produced by changing the length, wattage, insulation and voltage.
- Backed by the 35+ years engineering expertise of the Tempsens Group
FAQ
Frequently Asked Questions
Find answers to frequently asked questions related to Floor Heating Cables.
You may use cables designed for electric floor heating that are equipped with XLPE, PTFE, FEP, or ETFE insulation and PVC (HR-FR) jacket outside. Tempsens has many different models of heating cables ranging from 6 W/m to 17 W/m in size to accommodate a variety of floor areas and heat loads required by the installation.
Electric floor heating cables create heat via resistive heating. The electric current flows through a CuNi resistance conductor within the cable, converting electrical energy to heat which then radiates upward from the floor into the room via the covering of the floor.
Tempsens offers floor heating cables that can warm a room as the sole source of heat. Because of the uniform cable spacing and an electronic thermostat, the whole area is evenly heated without having any cold spots.
Electric underfloor heating cable has no moving parts, no valves and no water; therefore it does not have any maintenance requirements. As compared to Hydronic systems which require periodic service and are susceptible to plumbing blockages, Tempsens heating cable floor systems will not require any maintenance throughout their entire warranty period.