Calibration Services

Shop Now

Tempsens Calibration Centre is an independent unit of Tempsens instruments (I) Pvt. Ltd. We have calibration laboratories at Vadodara (Temperature Range for Contact Type Sensors -196 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C) and Bangalore (Temperature Range for Contact Type Sensors -35 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C).

It is the only private sector company in the country with accredited Fixed Point Temperature calibration Laboratory. The lab has highly stable calibration furnaces, measuring instruments and accurate master sensors traceable to National and International Standards. The calibration centre functions as per ISO / IEC17025 standards. Calibration of contact type sensors can be made in the temperature range of -196°C to 1600°C and Calibration of non-contact type sensors can be made in the temperature range 0°C to 3000°C. Further, the laboratory offers both in house and on-site temperature calibration.

"Tempsens calibration Centers - Udaipur, Vadodara, Bangalore"   

        

Unique Advantages

  • Fixed point cells calibration
  • One of the best C.M.C.
  • ISO/IEC 17025 Accreditation
  • Provide on-site calibration
  • Prompt and Fast Services
  • Covers wide range -196°C to 3000°C with NABL Certificate.

In House Calibration Facility:

In house calibration facility for contact and non-contact type sensor traceable to National and International standards. Best Measurement Capabilities and temperature range is as shown in the table

Quality Measured/Instruments Temperature Range Calibration & Measurement Capability

Contact Type RTD, Thermocouples 

-196°C

0.05°C

-80 to -38°C

0.05°C

-38°C to 0°C

0.03°C

0°C to 140°C

0.04°C

140°C to 250°C

0.04°C

250°C to 650°C

0.12°C

650°C to 1200°C

1.3°C

1200°C to 1600°C

2.6°C

Non-Contact Pyrometer

0°C to 250°C

1.5°C

250°C to 500°C

2.4°C

500°C to 1500°C

2.5°C

1500°C to 1700°C

3.2°C

1700°C to 3000°C

5.84 °C

Fixed Point Calibration Facility:

We are the first private company to provide fixed-point temperature calibration for Triple point of water (Tpw), Gallium (Ga), Tin (Sn), Zinc (Zn) & Aluminum (Al) Cells.

Fixed points are most accurate devices available for defining a temperature scale. Fixed point cells are designed to realize the liquid-solid equilibrium temperatures of certain high purity metal elements, for calibration of thermometers at ITS-90 fixed points. The best measuring capability and Temperature range for fixed-point calibration is shown in the table

Quality Measured/Instruments Temperature Range Calibration & Measurement Capability

Calibration of SPRT/PRTS/ THERMOCOUPLES at

Triple Point of Water (0.01°C)

0.0038 °C

Melting Point of Gallium (29.7646°C) 0.0065 °C
Freezing Point of Tin (231.928°C) 0.0065 °C
Freezing Point of Zinc (419.527°C) 0.0071 °C
Freezing Point of Aluminum (660.323 °C) 0.0075 °C

Calibration of Thermocouple at Secondary Fixed Point


 

Freezing Point of Gold (1064.18 °C) 0.0072 °C
Freezing Point of Palladium (1554.8 °C) 0.0083 °C

Address

Udaipur: Tempsens Calibration Centre
B-188A, Road No.5, M.I.A., Madri,
Udaipur - 313003 - Rajasthan - INDIA
Phone:91-294-3507715
Email: lab@tempsens.com
Baroda: Tempsens Calibration Center
TF- 304, Florance classic,
10, Ashapuri Society,
Near Unnati School
Akota, Baroda - 390020 (Gujarat)
Mob. 09327157887
Email: gujarat@tempsens.com 
 
Bangalore: Tempsens Calibration Center
No.7, Ist Main Coconut Garden
Nagarabhavil Main Road
Bangalore-560072 (K.N)
Mob. 09343183607
Email: bangalore@tempsens.com