Automatic Dry Block Calibrator (CALsys -30/110 Autocal)

Highly Accurate & Automatic Dry Block Calibrator for Industrial/Laboratory Field Use

Temperature Range: -30 to 110°C

Stability: ±0.04°C at -30°C, ±0.06°C at 0°C, ±0.07°C at 110°C

Uniformity: ±0.05°C at -35°C, ±0.07°C at 0°C, ±0.08°C at 110°C

In stock
SKU
CALsys -30/110 Autocal

Part Code: CALsys -30/110 Autocal

$4,352.26

Details

CALsys -30/110 Autocal is a Highly Stable Furnace for calibrating RTD. It offers a temperature range of -30 to 110°C. This calibrator can be used on-site for high-temperature calibration and applications like aerospace, oil gas petrochemical, pharmaceutical industry, electric power, automotive and material process industry. The comparison volume is a metallic fixed block of special material, which has a diameter of 32 mm and 120mm long. Low-temperature dry block furnace based on thermoelectric cooling circuitry.

The CALsys -30/110 Autocal is an automatic temperature of the calibration system for thermocouples and RTDs. The system consists of Temperature bath PC software, which together contributes to the whole cycle of the auto-calibration process. The system accepts 4 channels, 4 thermocouples, 4 RTDs.The channel configuration can be done with an LCD display via a touch screen keypad. The thermocouple microvolt & RTD ohm reading for each channel is monitored with CJC compensation. After the calibration process complete the PC software generates a report of actual calibrated values for inputs.

Specifications

Temp Range -30 to 110°C
Stability ±0.01°C at -30°C
±0.06°C at-0°C
±0.07°C at 110°C
Uniformity ±0.05°C at -30°C
±0.07°C at 0°C
±0.08°C at 110°C
Temperature Resolution 0.1°C
Heating Time 10 min
Cooling Time 25 min 
Fixed Insert Dimension 32 mm
Depth
120 mm
Method of control Digital Self Tuned PID Controller
Computer Interface RS - 232
Power Requirement 230 VAC, 500 W (50Hz)
Dimensions 380(H) x 170(W) x 188(D)mm
Instrument Weight 11 Kg(approx.)
Environmental operating conditions 0°C to 40°C, 0% to 90% RH (non-condensing)
Specifications valid in environmental conditions 13°C … 25°C
Input Four Channels (One master and three test sensors), high-quality LEMO connector suitable for both T/C and Rtd.
 Software The calibrator will be provided with software for data recording (Manual Mode) and report generation in Auto Mode.
Data Logging Data Logging facility with logged data export to the computer through  LAN port (Optional USB)

 

Key Features

  • High Accuracy
  • High Stability and Uniformity
  • Wide Temperature Range
  • PC Interfacing
  • Simple to Use and Cost Effective

Accessories

Standard Accessories

  • Reference Standard PRT…Part No.TPRT-A-300
  • NABL accredited calibration certificate - 3 point(Optional)
  • Software - Including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME.
  • Operational Manual

Standards

CE Certified