Calsys -100/40 Portable ,FPSC system based low temperature calibrator

Temperature Range: -100 °C to 40 °C

Stability (30min): ±0.04 °C or Better

Radial Uniformity: ±0.08°C or Better

In stock
SKU
Calsys -100/40

Part Code: Calsys -100/40

$0.00

Details

Calsys -100/40 offers easy to use portable low temperature calibrator with temperature range from -100 to 40°C. It is a highly stable standard furnace for calibrating RTD. This calibrator can be used on site for ultra low temperature calibration and also find application in aerospace, oil gas petrochemical, pharmaceutical industry, electric power, automotive and material process industry. The comparison volume is a metallic fixed block of special material, which has a fixed insert with 120mm long.

Low temperature dry block furnace based on FPSC cooling system.This model provides special design isothermal enclosure which can calibrate sensor against the calibrator. Temperature of the calibrator is set and controlled by a self tuned PID controller with automatic super fine adjustment.

Specifications

SPECIFICATIONS

Temperature Range* -100°C to 40°C
Stability (30 Min) ±0.04 °C or Better
Radial Uniformity ±0.05°C or better
Immersion Depth** 150 mm
Method of Control Self tunned PID controller
Cooling Time 70 Min ( Ambient 25°C to -100°C)
Stabilization Time 15-20 Min
Resolution 0.1 °C (0.01 Optional)
Display LCD, °C, or °F user-selectable
Size (H x W x D) 545(H) x 245(W) x 350(D) mm
Weight 16Kg
Power Requirements 230 VAC, 350W
Computer Interface USB
Calibration Accredited calibration certificate provided (Optional)
Environmental Operating Conditions 12 °C to 35 °C, 0 % to 90 % RH (non-condensing)
Specifications valid in environmental
conditions
15°C … 30°C
Input (Autocal -100/40) Four channels (one master and three test sensors).high
quality universal LEMO connector suitable both for T/C (J,
K, N,T,R,S, B type) and Rtd
Software (Autocal -100/40) The calibrator will be provided with software for data
recording (Manual Mode ) and Excel generation in
Auto Mode
Data logging (Autocal -100/40) Data logging facility with logged data export to computer
through LAN port ( optional USB)

* At 28C Ambient Temperature
**120mm Deep Plus 30 mm top insulation 

Note : Customized options available for resolution and insert construction

Key Features

  • Wide TemperatureRange (-100 to 40°C)
  • Lightweight, portable
  • Speed
  • Accuracy and performance
  • Cooling Technology
  • Accredited calibration
  • Computer Interface

Accessories

  • Insert
  • Reference Standard RTD
  • Calsoft Software
  • Operational Manual
  • Carry Case
  • NABL accredited calibration certificate (Optional)

Standards

  • CE Certified

Reviews

Write Your Own Review
You're reviewing:Calsys -100/40 Portable ,FPSC system based low temperature calibrator