Autocal 100-40 Dry Block Calibrator by Tempsens, manufacturer & supplier in UAE. Ensures reliable, fast, and accurate temperature calibration performance.
Part Code: Autocal-100/40
Temperature Range*: -100°C to 40°C
Stability (30 Min): ±0.04 °C or Better
Cooling Time: 70 Min ( Ambient 25°C to -100°C)
Method of Control: Self tunned PID controller
Calibration: Accredited calibration certificate provided
Autocal-100/40 offers easy to use portable low-temperature calibrator with a temperature range from -100 to 40°C. It is a highly stable standard furnace for calibrating RTD. This calibrator can be used on-site for high-temperature calibration and also find application in aerospace, oil gas petrochemical, pharmaceutical industry, electric power, automotive and material process industry.
SPECIFICATIONS
| Temperature Range* | -100°C to 40°C |
| Stability (30 Min) | ±0.04 °C or Better |
| Radial Uniformity | ±0.05°C or better |
| Immersion Depth** | 150 mm |
| Method of Control | Self tunned PID controller |
| Cooling Time | 70 Min ( Ambient 25°C to -100°C) |
| Stabilization Time | 15-20 Min |
| Resolution | 0.1 °C (0.01 Optional) |
| Display | LCD, °C, or °F user-selectable |
| Size (H x W x D) | 545(H) x 245(W) x 350(D) mm |
| Weight | 16Kg |
| Power Requirements | 230 VAC or 110 VAC 50/60 Hz 350W |
| Computer Interface | USB/ LAN |
| Calibration | Accredited calibration certificate provided (Optional) |
| Environmental Operating Conditions | 12 °C to 35 °C, 0 % to 90 % RH (non-condensing) |
| Specifications valid in environmental conditions | 15°C … 30°C |
| Input (Autocal -100/40) | Four channels (one master and three test sensors).high quality universal LEMO connector suitable both for T/C (J, K, N,T,R,S, B type) and Rtd |
| Software (Autocal -100/40) | The calibrator will be provided with software for data recording (Manual Mode ) and Excel generation in Auto Mode. |
At 25°C Ambient Temperature
**120mm Deep Plus 30 mm top insulation
Note : Customized options available for resolution and insert construction
- Wide Operating Range (-100°C to 40°C)
- Lightweight, portable
- Speed
- Accuracy and performance
- Cooling Technology
- Accredited calibration
- Computer Interface
- NABL accredited calibration certificate – 3 point(Optional)
- Software – CalSoft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging.
- Operational Manual
- Tempsens makes customized carry case is a rugged, safe perfectly designed to carry our new Calsys -100/40 & Autocal -100/40 calibrator and different accessories.