Enquire Now
Site Logo
blog December 15, 2020

Self Powered Neutron Detector

Download PDF

Self-Powered Neutron Detectors has been used effectively as in-core flux monitors in nuclear power reactors world-wide. The basic properties of these radiation sensors include nuclear, electrical and mechanical characteristics. The proper choice of the self-powered detector emitter to provide the proper response time and radiation sensitivity desired for use in an effective in-core radiation monitoring system.

SPND can be of many types. The typical inconel type SPND is a coaxial cable consisting of an inner electrode of inconel (the emitter), surrounded by insulation and an outer electrode of inconel (the collector). Preferably, the lead cable and detector sections are integral, i.e. the signal wire of the lead cable mates directly to the emitter; the insulation of both sections are identical and the collector of the detector section is also the outer sheath of the lead cable section.In Self-Powered Neutron Detectors (SPNDs), the interactions of neutrons and atomic nuclei are used to produce a current which is proportional to the neutron fluence rate (flux).
Self Powered Neutron Detector Cable

Application of SPND:

  • It is used for core flux measurement in Nuclear
  • The design of SPND is rugged, simple, flexible and long
  • It is used for high flux-high
  • Indication or
  • It is used for mapping or permanent

Advantages of SPND:

  • SPND doesn’t require power
  • SPND structure is simple and
  • SPND has small mechanical size which is desired for in-core
  • The stability of SPND is good under temperature and pressure
  • SPND generates a reproducible linear

Technical Specification of Inconel type SPND:

For Detector:

Emitter MaterialInconel 600
Emitter Diameter1.40 mm
Sensitive LengthCan be made upon request
InsulatorMgO
Collector MaterialInconel 600
Outer Diameter of detector3.00 mm

 For Cable: 

Length of CableCan Be made on request
InsulatorMgO
Sheath MaterialInconel 600
Outer Diameter of Cable1.60 mm

 Characteristics: 

Measured QuantityNeutron Flux
Insulation resistance

( at room temperature)

≥ 1 X 1012 Ώ at 250 VDC
Insulation Resistance

(at 300°C)

≥ 5 X 108 Ώ at 250 VDC

 

Related Articles

CONTACT

Let’s Talk About Your Thermal and Cable Needs

Have questions about Thermal Engineering Solutions, Electric heating solutions, or specialized cable? We're here to provide tailored solutions. Reach out today, and let’s collaborate on your next project!

Tempsens Arrow