Enquire Now
Site Logo
blog May 18, 2021

Difference between Extension, Compensating & Thermocouple Conductors

The

thermocouple

conductors are used to manufacture thermocouple sensors to sense the temperature directly; however extension & compensating conductors are used in extension/compensating cables that used to extend the thermocouple mV signal from thermocouple sensors to panel. Extension & compensating grade conductors have typically lower temperature limit & accuracy as compared to Thermocouple grade conductors.

Major differences among three types of conductors are as follow

Thermocouple Conductors

  • These are called original conductors used to make thermocouple sensor.
  • It has special limits of accuracy (Class 1)as per IEC 60584.3 that is 1 . 5 °C or 0 . 4 % of temperature.
  • Temperature ranges of these conductors are maximum measuring range of thermocouple type.
  • Costly as compared to Extensions & Compensating conductors.
  • In flexible thermocouple wire & cables these conductor are used.

Extension Conductors

  • Extension grades conductors have same conductor material as of thermocouple one but with lower accuracy.
  • It has standard limits of accuracy (Class 2)as per IEC 60584.3 that is 2.5 °C up to 200 °C
  • Temperature ranges of these conductors are maximum up to 200 °C
  • Costly as compared to compensating but cheaper than thermocouple grades conductors.
  • These conductors are used to make wires & cables, same cables are used to extend the thermocouple output mV signal to panel.
  • Extension conductors not available with R/S/B type thermocouple

Compensating Conductors

  • Compensating grades conductors are copper based material having similar
  • characteristicsas of thermocouple over a very limited temperature range.
  • It has standard limits of accuracy (Class 2)as per IEC 60584.3 that is 2.5 °C up to 100 °C only
  • Temperature ranges of these conductors are up to 100 °C only.
  • Cheapest among all
  • hese conductors are used to make wires & cables, same cables are used to extend the thermocouple output mV signal to panel.
  • Maxallowed Cable temperature range is up to 100 °C.
  • Available in KCB & KCA (Ktype) RCA ® type), SCA (Stype ) , BC ( BType) thermocouple compensating conductors

Related Articles

CONTACT

Let’s Talk About Your Thermal and Cable Needs

Have questions about Thermal Engineering Solutions, Electric heating solutions, or specialized cable? We're here to provide tailored solutions. Reach out today, and let’s collaborate on your next project!

Tempsens Arrow